Thrust and Thrust Reverser Control Levers


Back to Pedestal


img_3.png

Usage

ENGINE 1(2)(3)(4) MASTER LEVER

  • When put to ON:

    • The FADEC initiates an automatic engine start sequence, provided the ENG START selector is set to IGN START position, or for more information, Refer to DSC-70-30 Automatic start sequence.
    • Turns on the igniters and the fuel, if the ENG MAN START pb-sw is set to ON.
  • When put to OFF:

    • Shutdowns the engine or aborts the start sequence. The FADEC resets.

ENGINE MASTER 1(2)(3)(4) LIGHT

  • FIRE (red):

    • A fire is detected on the corresponding engine.
    • Associated with the following ECAM alerts:
      • ENG 1(2)(3)(4) FIRE (IN FLIGHT).
      • ENG 1(2)(3)(4) FIRE (ON GROUND).
  • FAULT (amber):

    • An automatic start sequence aborts, or
    • The HP fuel valve position is abnormal.
    • Associated with the ECAM alert ENG 1(2)(3)(4) HP FUEL VLV FAULT
    • The overthrust protection is active and the FADEC automatically shuts down the engine.
    • Associated with the ECAM alert ENG 1(2)(3)(4) CTL SYS FAULT