Maintenance Panel
Description
The Airbus A380 overhead maintenance panel provides a central interface for accessing various aircraft systems and performing maintenance checks. The panel is divided into sections, each dedicated to specific systems or functions.
Here's a breakdown of the major systems covered on the overhead maintenance panel:
OXYGEN
RESET pb
Maintenance personnel uses this pushbutton to reset the control circuit, after the oxygen system has been used.
- When pressed:
- Resets the oxygen system: The PAX SYS ON light (on the OXYGEN panel) goes off.
- When the reset is completed, ON goes off.
- The reset lasts approximately three seconds.
- FAULT:
- The reset has failed.
GND HYD
See Hydraulic Panel for more information.
FUEL
REFUEL pb-sw
Refueling is usually initiated from the external REFUEL panel, that is under the aircraft belly fairing. However, refueling can also be initiated from the cockpit, via the REFUEL pb-sw. Cockpit refueling takes a priority over a refueling initiated from the external REFUEL panel.
- OFF:
- Refueling from the cockpit is not activated.
- ON:
- When pressed, refueling from the cockpit is enabled.
- END/ON:
- Refueling was initiated from the cockpit and has completed, or has aborted.
- If the FQMS aborts refueling, the light flashes.
- This is associated with the following ECAM alert: FUEL REFUEL FAULT
AUTO GND XFR pb-sw
- OFF:
- Automatic ground transfer is not active.
- Note: Only manual transfers can be initiated from the external REFUEL panel.
- ON:
- When pressed, automatic ground transfer is activated to automatically obtain the ground CG target.
- Note: All transfer pumps must be ON to perform an automatic ground transfer.
- END/ON:
- Automatic ground transfer is completed, or is aborted by the FQMS.
- If the FQMS aborts the automatic ground transfer, the light flashes.
- This is associated with the following ECAM alert: FUEL AUTO GND XFR FAULT
BAT
BAT 1/2/APU/ESS selector
Selects the battery in order to display the voltage.
BAT Display
Displays the voltage of the selected battery.
ENG
FADEC GND PWR pb
- AUTO:
- The aircraft electrical network or the FADEC alternator automatically supplies the FADEC.
- ON:
- On ground, the aircraft electrical network supplies the FADEC for 10 min, provided that:
- The ENG FIRE pb-sw is not pressed
- The FADEC is not self-powered.
- The FADEC is self-powered when N2 is above 12.5 %.
MAINT
GND CONNECTION pb (INOP)
- OFF:
- The maintenance personnel cannot connect a PMAT to the NSS AVNCS side via the plugs distributed throughout the aircraft.
- ON:
- The maintenance personnel pressed the MAINT GRND CONNECTION pb-sw .
- For maintenance purposes on ground, the maintenance personnel can connect a PMAT to the NSS AVNCS side via the plugs distributed throughout the aircraft.
ELEC
REMOTE C/B CTL pb
- OFF:
- Normal operation.
- ON:
- The remote C/B controller is ON, and can be displayed on the OIT.
- This controller is for maintenance purposes only.
NSS
Network Server System (NSS) communication between the NSS CAB side and the FLT OPS side.
NSS GATELINK pb-sw
- ON:
- The Terminal Area Wireless LAN Unit (TWLU) is on.
- Communication between NSS and ground via gatelink is possible.
- OFF:
- The Terminal Area Wireless LAN Unit (TWLU) is off.
- Communication between NSS and ground via gatelink is not possible.
NSS CAB DATA TO NSS pb-sw
- ON:
- Communication between NSS CAB side and FLT OPS is enabled.
- OFF:
- Communication between NSS CAB side and FLT OPS is disabled.
AIR
OVHT COND AIR FANS RESET pb
In the case of overheat of a ventilation system fan, the affected fan automatically stops. The Maintenance personnel uses this pushbutton to restart the fan.
- Not illuminated:
- No overheat is detected.
- FAULT illuminated:
- One or several fans of the ventilation system failed due to overheat.
- The FAULT light is not always associated with an ECAM alert, depending on the location and the number of the
affected fan(s). For example:
- If one primary cabin fan fails, the ECAM alert COND ONE PRIMARY CABIN FAN FAULT triggers
- If one cabin air extraction fan fails, no ECAM alert triggers. There is no operational impact.
- When pressed, resets the affected fan(s). When the reset is completed and successful, the FAULT light goes off.
VENT
AVNCS GND COOLG pb
- AUTO:
- Normal operation of the supplemental cooling system.
- OFF:
- The supplemental cooling system is off.
- FAULT:
- The supplemental cooling system is failed.
- Associated with the following ECAM alerts:
- VENT COOLG SYS 1(2) OVHT
- VENT COOLG SYS PROT FAULT
Miscellaneous
SVCE INT OVRD pb
- AUTO:
- The service interphone is automatically inhibited in flight.
- ON:
- If the service interphone remains abnormally inhibited on ground, the ground crew can manually activate it, by pressing the SVCE INT OVRD pb.
GND HF DATA LINK
- AUTO:
- HF data communication is automatically inhibited on ground.
- OVRD:
- For maintenance purposes, the ground crew can press the GND HF DATALINK pb-sw to activate HF data communication on ground.
CKPT DOOR LCKG SYS
Maintenance personnel uses this pushbutton-switch to turn off the Cockpit Door Locking System (CDLS), in order to ease ground operations (e.g. servicing, cleaning, maintenance, etc.).
- AUTO:
- The CDLS is operative.
- When pressed, turns off the CDLS.
- OFF:
- The CDLS is off, and the door is free to open from the cockpit or from the cabin.
- When pressed, turns on the CDLS.