APU Fire
Description
The APU compartment has a fire protection system, with:
- A fire detection system
- One extinguisher bottle that discharges extinguisher agent
- An APU Fire panel, with assigned pushbuttons. These pushbuttons can be used to isolate the APU from the other aircraft systems, and control fire extinguishing.
- Visual and aural alerts.
Usage
APU FIRE pb
- Nominal position: Dark
- No fire is detected.
- Normal position: Illuminated
- Fire is detected in the APU compartment.
- Associated with the following ECAM warning: APU FIRE (Refer to Procedure)
- The light remains on, until the fire is extinguished, regardless of the position of the APU FIRE pb.
- Guard open, Pushed out
- All associated systems are isolated from the APU
- The aural fire warning stops
- The fire extinguishing system is armed, the bottle is ready to discharge.
AGENT pb
- OFF
- The fire extinguisher bottle is not armed.
- SQUIB
- The squibs of the fire extinguisher bottle are armed. The fire extinguisher bottle is ready to discharge extinguisher agent.
- When pressed, the extinguisher bottle discharges and the SQUIB light goes off.
- DISCH
- The fire extinguisher bottle discharges or is empty.